Adjustable LED light for Hyperbaric chambers

690.00$

Features

  • 4.2 Watt LED bulb equivalent to 30 Watt Halogen bulb
  • Adjustable integrated mounting plate
  • Low heat with high-performance heat sink
  • 3-pin Male Marsh Marine Connection
  • Optional magnetic base available
  • Optional blue lens filter available

 Specifications

  • Lamp type: White 4.2 Watt LED (equivalent to 30 Watt Halogen bulb)

 Electrical Specifications

  • Operating Voltage Range: 10-28 VDC
  • Input Power: 5 Watts (maximum)
  • Beam Angle: 30°
  • Light Level: 300 lumens

 Mechanical Specifications

  • Housing: 6061 Aluminum
  • Finish: Black Hard Anodized, MIL-A-8625, type III class 2
  • Pressure Rating: 1000 fsw (300 msw)

Mating Connectors

  • 3-pin Marsh Marine: RMG-3-FS (not included)
  • Locking Sleeve: Delrin – Marsh Marine: G-FLS-D (not included)
  • Locking Sleeve:  Stainless Steel – Marsh Marine: G-FLS-S (not included)

 Dimensions

  • Height: 3.15 inches (80 mm)
  • Body Diameter: 3.3 inches (84 mm)
  • Mounting Plate: 4.5 inches (114 mm)
  • Weight: 1.50 lbs (0.68 kg)

*Mounting Holes – Industry Standard Two 0.25 inch (6.35 mm) diameter mounting holes with a 3.82 inch (97 mm) spacing.

 

In Stock

Air Filter System – 3 stage EN12021

1,200.00$

Features:

  • The first stage is a general purpose filter that removes liquids and solids down to 5 microns
  • The second stage filter removes sub-micron particles and oil aerosols down to 0.01 micron before the final stage
  • The third stage removes oil vapors and odors using a carbon cartridge

Specifications:

  • Max. Inlet Air Pressure: 250 psig
  • Max. Temperature: 150° F
  • Final Stage Flow Range: 100 scfm
  • Inlet & Outlet Valves (2): 3/4 FNPT, Brass
  • Valve Nipples (Brass): # 10 JIC
  • Inlet & Outlet Gauge: 0-300 psi
  • Frame: Marine Grade Aluminum 1in. square tubing

Dimensions:

  • Height: 21 in.
  • Length: 30 in.
  • Top: 8 in.
  • Bottom: 12 in.
  • Weight: 34 lbs.

In Stock

Amcom II – Double Lock intercom

1,725.00$

Features

  • Two Modes of Operation – 2-Wire Mode and/or 4-Wire Mode
  • Separate volume controls for operator and each lock
  • Separate on/off controls for each lock
  • External 12 VDC connection

Amcom ™ II 2820A-4003 Double Lock Chamber Communicator Includes

  • (1) Hand-Held Push-to-Talk Microphone: Part Number 2405-28
  • (1) 12 VDC Slide Terminal Gel-Cell Rechargeable Battery: Part Number 2890-05 – Expected life: 20 hrs
  • (1) MS Connector – 14 Pin Female: Part Number MS-3106A-20-27S
  • (1) MS Cable Clamp 20/22 Shell: Part Number MS-3057-12A
  • (1) Power Cord: Part Number P-2392
  • (1) User Manual

Specifications

  • Power: 115/230 VAC, 50-60Hz
  • Audio Output Power: 20 Watts
  • Back-up Power: Rechargeable 12 VDC Slide Terminal Gel Cell
  • Rear Panel Connection: MS 14 Pin Male with Mating Connector
  • Entertainment Input: 2 RCA jacks for (2820A-4003E only) audio input, signal is mixed internally for a stereo input/monaural output
  • Dimensions: 8 in. H x 10.125 in. W x 7.5 in. D(20.3 cm x 25.7 cm x 19.1 cm)
  • Weight: 15 lbs (3.6 kg)

Tech Note

All communicators will transfer topside noise to the diver when using the radio speaker only. To eliminate background noise and achieve clear concise communications, use a Push-to-Talk microphone, headset, or a Remote Walk-and-Talk with a headset.

 

In Stock

Amron Oxygen Treatment Hood

120.00$

Features:

  • Latex Neck Seals (Trimmed P/N: 8891-005-00 and Untrimmed P/N: 8891-005) are compatible with BOTH OLD Neck Ring (P/N: 8891-001) and 2014 improved Neck Ring (P/N: 8891-011)
  • Both versions of the Oxygen Treatment Hood P/N: 8891-010 fit BOTH OLD and 2014 improved Neck Rings
  • CE and FDA Registered
  • Optimum cooling and noise reduction
  • Reusable neck ring (autoclavable)
  • Conveniently located hoses reduce bulk and improve comfort
  • Designed for simplicity, performance, economy, ease-of-use and safe effective cleaning
  • Innovative design allows patient to recline comfortably
  • Multipurpose port for gas analysis or entertainment option
  • Positive O-ring seal between hood and neck ring
  • Soft vinyl hood with extra-large optical quality window
  • Replaceable surgical latex neck seal with sized trim lines
  • Optional entertainment system with pneumatic headset
  • Replaces P/N: 8892

Note: Neck Seal comes installed on neck ring

Sterilization:

Please reference the Cleaning Manual located in the Attachments Tab on this web page for recommended cleaning instructions. Oxygen Treatment Hood can be sterilized using either gas sterilization method, however multiple cycles of gas sterilizing over time will shorten the products working life.

Component Breakdown:

  • P/N 8891-010: Vinyl Hood with Optical Window
  • P/N 8891-005-00: Untrimmed Latex Neck Seal
  • P/N 8891-011: Neck Ring
  • P/N 8891-15: O-ring
  • P/N 8891-25: Multipurpose Plug

Note: The neck seal contains natural rubber latex which can cause allergic reactions. Please select our Model 8891-03 Medical Grade Silicone Hood Assembly if you believe the patient may have a latex sensitivity or allergy.

Caution: Federal law (USA) mandates that Amron can only sell this product to physicians and/or licensed clinical practitioners.

Specifications:

  • Neck Ring: Polycarbonate (Autoclavable)
  • Hood Ring: PVC
  • Hood: Clear soft vinyl (PVC)
  • Hood Window: Optical press polished vinyl
  • Neck Seal: Latex
  • O-ring, Neck Ring: Nitrile
  • Multipurpose Ring: Nitrile
  • Supply and Exhaust Ports: Male 22 mm
  • Multipurpose Port: 0.5 in. (1.27 cm) diameter
  • Diameter: 12.5 in. (31.75 cm)
  • Height: 13.5 in. (34.29 cm)
  • Weight: 1.37 lbs. (21.9 oz.)

 

In Stock

Analox SDA Oxgen Analyzer, 4-20mA output

1,950.00$

Features

  • Easily configured
  • Interchangeable sensors and software allowing greater flexibility
  • Available as either a panel or rack mount analyzer

Specifications

  • Range: 0 to 100% or 0 to 3000mBar
  • Display resolution: 0.01%
  • Alarms: 1 x high going, 1 x low going (fully adjustable)
  • Pressure range: 700 to 1,300 mBar
  • Recommended flow rate: 0.2 to 1.0 litre/minute

In Stocks

AVOX Bibs Mask System

1,350.00$

Features:

  • Full head harness for added comfort during long administration
  • Exhausts exhaled gases over board, permitting minimum ventilation of the chamber
  • Demand Regulator permits constant flow operation
  • Demand Regulator designed to operate with constant inlet pressure of 65 to 125 PSI over chamber pressure

Specifications:

  • Weight: 3.9 lbs.

In Stock

Bibs Mask 350 M

1,580.00$

Features:

  • Third party Tested and Certified by NUI to Norsok U-101:1999 and Verified by DNV
  • Easy Breathing (light inhalation and exhalation resistance, resulting in a low work of breathing)
  • Rugged Regulator Housing with Stainless Steel Valve Assemblies
  • Tool-less Removal of Demand and Exhaust Valve Assemblies for ease of maintenance and service
  • Pneumatically Balanced Demand Regulator with fine tune adjustment
  • Pneumatically Balanced Exhaust Regulator with overboard dump, permits minimum ventilation of the chamber
  • Vacuum Relief Valve Included
  • Gas Router and CO2 Purge Mechanism Attached to the Valves
  • Double Diaphragm Design with Removable Diaphragms and locking Diaphragm Covers for proper alignment and compression
  • Ultrafit, Hi-Comfort Silicone Oral Nasal, designed to fit most faces and designed to accommodate a microphone option
  • Full Head Harness for added comfort during long administration
  • Pressure and Collapse tested 10 ft. Hose Assembly with Quick Disconnects included
  • For use with Air, Oxygen, or Heliox
  • A unique microphone (Part #: 550-0010-01) can be linked to an Amcom ™ series communicator, allowing the person inside the chamber to clearly communicate with people outside the chamber
  • CE 607930
  • US Patent No. 8,336,547
  • Int. PCT. Pat. App. No. US2012/066144 pending

350M BIBS Mask – P/N: 350M-01 Includes:

  • (1) 10 Foot Hose Assembly – P/N: 540-0004-01
  • (1) Oxygen Cleaned Quick Disconnect Socket – Brass – P/N: 59853-00
  • (1) Oxygen Cleaned Quick Disconnect Socket – P/N: 18969-00
  • (1) 350M BIBS Mask User’s Manual – P/N: 350M-UM
  • (1) Certificate of Conformance

Warning: The Amron 350M BIBS Mask was designed and is for use within a hyperbaric chamber only. It is NOT intended for and must NOT be used underwater.

 

In Stock

CO2 analyzer , 4-20mA output

650.00$

E+E Elektronik understand that instruments in livestock barns or greenhouses are exposed and deemed as demanding environments.The EE82 CO2 transmitter for demanding applications addresses this worry by serving as a robust measuring transmission device that can handle pollutants, humidity, herbiocides, and increased ammonia concentration in the atmosphere. The key to this is the functional housing of EE82 that also included a unique filter to manage these hazards.
The filter diffuses the air into the enclosure and further diffuses through a second membrane that is connected to a measuring cell for CO2.

CO2 Scrubber – 7Lt

750.00$

Features

  • Dependable motor, completely sealed with brushless design
  • Two versions available: adjustable pre-set fan speed or externally controllable fan speed
  • 24 VDC, 2A power supply (pre-set fan speed)
  • Externally controlled version requires an optional fan speed control unit
  • Canister can hold approximately 16.5 lbs (7.5 kg) of CO2 adsorbent
  • The canister is connected to the motor by a bayonet locking mechanism, so it can be easily replaced and/or refilled

Includes

  • User Manual

Specifications

  • Power Supply: 24-28 VDC, 2 amps
  • Rotating Speed (without canister, atmospheric pressure): 1400-4000 RPM
  • Operating Pressure: Max. 600 PSI/42 bar (420 MSW)
  • Dimensions: 9.7 in. H x 8.9 in. W x 16.6 in. D (24.5 cm x 22.6 cm x 42.2 cm)
  • Weight Complete Unit (empty canister): 18.3 lbs (8.3 kg)
  • Weight Complete unit (full canister): 35.3 lbs (16 kg)

 

In Stock

Drager Oxylog 100 Ventilator + Chamber connections

7,500.00$

​The Oxylog® 1000 offers first aid ventilation of patients in emergency situations. Designed to be used outdoors, its intuitive operation, robustness and transportability make the Oxylog® 1000 complete in its class. The ventilator has integrated audible and visual alarms that monitor both the airway pressure and supply pressure to aid in patient safety.

All functions are pneumatically operated, so the ventilator does not depend on any electrical power source. Thanks to its fundamental design, the Oxylog® 1000 also stands for great reliability, ready to meet rough conditions during your mission.

Call Us

Dwyer 10-100 lpm Flowmeter

75.00$

Features

  • Exceptionally tough
  • 2 inch scale
  • Stainless steel valve and connections

Specifications

  • Scale: 2 in.
  • Scale Type: LPM Air
  • Range: 10-100
  • Options: Stainless Steel Metering Valve & Connections

Pipe Connections

  • VFA and VFB: 1/8 in. NPT (1/4 in. NPT on VFB 85 and 86)
  • O-rings: Buna-N
  • Pressure Rating: 100 PSI Max.

Temperature Rating

  • VFA and VFB: 150° Max.

Accuracy

  • Model VFA: 5% of full scale

Model VFA Dimensions

  • Dimensions: 4-3/16 in. H x 1 in. W x 1-1/4 in. D
  • BV or SSV (open): 2-1/16 in.

Call Us

Hyperbaric infusion pump

3,200.00$

The HCI Model HBIP is intended for infusing patients treated within a hyperbaric chamber. The HBIP is a Baxter Flo-Gard 6201 pump adjusted to pump required pressure

(up to 3ata -absolute pressure) to infuse the patient.

The pump is placed outside the chamber

where special tubing isn’t required to

penetrate into the chamber.

Hyperbaric inside Fan Coil unit – 7kW

750.00$

Features

  • Feathered edge fan blade for super quiet operation
  • Stainless steel rotor ball bearings, giving long life operation
  • Wide voltage operation
  • Brushless electronic commutation provided by dependable solid state circuitry
  • Electronic locked rotor protection, current limited, with automatic restart capability
  • Per MIL STD 461 EMI standards per FCC part 15, Subpart J of Docket 20780, Class A and B radiated and conducted Emissions
  • Operating temperature range of -10 to 70 C
  • UL Yellow Card recognized (File No. E31293)

Specifications

  • Cooling & Heating Capacity: 4000 BTU/hr
  • Fluid Flow Rate Required: 3-6 GPM @ 5 PSIG
  • Fluid Media: 50% Ethylene or Propylene Glycol, 50% Water
  • Fluid Capacity: 1 Quart (approx)
  • Voltage: Nominal 24VDC, Min/Max: 12/28VDC
  • Speed: 3350 RPM, 230 CFM @ 25VDC
  • Current: 2 Amp (ambient), 5 Amp (peak)
  • Depth Rating: 250 FSW
  • Input/Output Fluid Connections: 1/2 in. male JIC, left or right side
  • Temperature Rating: 25° to 110°F (-4° to 43°C)

In Stock

Hyperbaric two way speaker with push to talk

520.00$

Features

  • 8 Ohm
  • 15 Watts speaker
  • Housing is die cast zinc with gray powder coat with 300 series stainless steel front panel

Dimensions:

  • Height – 5.5 in. (14 cm)
  • Width – 5.5 in. (14 cm)
  • Depth – 4 in. (10.2 cm)
  • Weight – 5 lbs (2.3 kg)

 Includes

  • 7 Pin MS Connector: Part Number MS-3106A-16S-1S
  • MS Cable Clamp 16S-1: Part Number MS-3057-8A

Stokta Var

Latex Neckseal Untrimmed

40.00$

Features:

  • Latex Neck Seals (Trimmed P/N: 8891-005 and Untrimmed P/N: 8891-005-00) are compatible with BOTH OLD Neck Ring (P/N: 8891-001) and 2014 improved Neck Ring (P/N: 8891-011)
  • Both versions of the Oxygen Treatment Hood P/N: 8891-010 fit BOTH OLD and 2014 improved Neck Rings
  • CE and FDA Registered
  • Integrated o-ring seal that allows for easy installation or removal
  • Numbered trim rings for accurate neck sizing

 

In Stock

Microphone – push to talk for Amcom II

120.00$

Features:

  • Noise-canceling
  • Excellent sound clarity
  • Push-to-talk
  • Color-coded banana plugs mate directly to the color coded inputs of all Amcom ™ Communicators

In Stock

Oxygen Analyzer

425.00$

Features:

  • Digital display has 0.1% resolution
  • Analyzer is water resistant and sealed
  • Splash proof on/off/on switch (with back light)
  • Internal temperature compensated O2 sensor
  • Low battery warning symbol in left corner of display
  • Ready to use out of the box after checking calibration either in air (20.9%) or 100% O2
  • Complete with a sensor flow cap/restrictor that allows you to read directly from a cylinder valve

Specifications:

  • Range: 0.0% to 100.0 % O2
  • Accuracy: ±1% at full scale
  • Response Time: 90% in <5 Sec.
  • Sensor Type: Galvanic (Electro Chemical)
  • Warranty: 12 Months
  • Stabilization Time: 15 minutes when first installed
  • Battery: 3 AAA 1.5V batteries
  • Operating Temp: 32° to 122° F (0° to 50° C)

C-Squared Oxygen Monitor – P/N: O2MONITOR Includes:

  • Internal O2 Sensor – P/N: D-13
  • Flow Cap/Restrictor
  • (3) AAA 1.5V Batteries
  • Deluxe Black Carrying Case

Call Us

Patient Monitor – VGA connection to chamber

1,925.00$

15″/17″color TFT display
Suitable for adult, pediatric and neonatal patients
Up to 3 slave screens on the main units for separate view
13 module slots for flexible configuration
MPM module with up to 8-hour data saving for patient transport
Advanced technologies including RM, ICG, BIS, etc.
Maximum 8 channels for IBP measurement
Friendly and configurable user interface
Ethernet or Wireless LAN networking
Maximum 120-hour graphic and tabular trends of all parameters

Silencer – Hyperbaric use – 85 dB guarantee

120.00$

Features

  • World Class Atomuffler superbly quiets Exponentially Perceived Noise (EPNdB)
  • Constructed entirely of corrosion resistant material for long life and maintenance-free performance

 

In Stock

SP phone

245.00$

Features

  • Safe and reliable transmission for chamber communications
  • Generates signal from sound waves, no electrical required

In Stock

Stopwatch – multifunction

50.00$

Features

  • 100 dual split re-callable memory
  • Continuous display of event time
  • Memory recall during operation
  • Take splits during recall mode
  • Large three row display
  • Measures to ten hours
  • Stroke/frequency
  • Time and calendar
  • Water resistant
  • Lithium battery
  • Five-year warranty

In Stock

TcPO2 ( 1 channel) with chamber connections

14,000.00$

The TCM CombiM configuration is designed specifically for neonatal and pediatric intensive care needs. It provides continuous, reliable, accurate, non-invasive and real-time transcutaneous tcpO2 and tcpCO2 information and comes with a range of high performing sensors.

The tcpO2 measurement, a differentiating feature of the TCM CombiM monitor, is a crucial parameter for patients in neonatal intensive care to avoid the risk of hyperoxia and its effects (eg. retinopathy in preterm babies). Indeed for high oxygenation rate, where SpO2 is not any more accurate, tcpO2 carries on providing a precious information concerning oxygenation of the tissue.

The TCM CombiM monitor combines an enhanced ready-to-use function with a unique gold-plated sensor technology in the tc Sensor 84 and tc Sensor 54, making it highly reliable, stable and robust. Real-time trending of measured parameters is displayed ensuring fast and immediate clinical intervention to critical changes.

The TCM CombiM monitor utilizes various communication protocols to interface with any patient monitoring system and PC.

 

Optimize your work routines

  • Intuitive color touch screen and Windows CE software for increased user-friendliness
  • High compatibility to interface with any patient monitoring system
  • On-board video tutorials
  • Built-in battery facilitates transport of the patient
  • Simultaneous viewing of all measurements
  • USB port for easy printing of reports
  • Patient-friendly sensor fixations for improved comfort

 

Increased patient safety

  • On-screen visualization of patient data in graphical or tabular format
  • Patient information automatically linked to measurements
  • Automatic linking of data and marking of events to a session
  • Real-time data storage
  • Continuous trend measurement

Call Us

Thermo – Hygromete

220.00$

Features

  • Bi-metallic thermometer is accurate to 1% of scale
  • Range 0° to 210° F (-20° to 100° C), certified to be accurate within ±3%
  • Used inside the sat system (Living chamber and Diving Bell)

Specifications

  • Temperature Range: -20 to 100°C and 0 to 210°F
  • Relative Humidity Range: 0 to 100%
  • Case: Solid Brass, gleaming finish, drilled for wall mounting
  • Dial Size: 6 in. overall Dia. (15.2 cm)
  • Weight: 3 lbs (1.4 kg)

In Stock

Water based hyperbaric fire extinguisher

390.00$

Model 240 Hyperbaric Water Based Fire Extinguisher: Part Number Model-240 Includes

  • (1) Wall Hanger
  • Owner’s Manual

Specifications

  • Water Capacity: 2.0 gal. (7.6 liters)
  • Maximum Pressure: 165 psi (11.3 bar)
  • Maximum Depth: 225 FSW
  • Dimensions: 7.0 in. Dia. x 30 in. H (18 cm x 76 cm)
  • Empty Weight: 6.50 lbs. (2.95 kg)

İn Stock